Installation Guide

CAUTION!
§ Do not tilt unit further than 30° off vertical during uncrating or installation.
§ Dispenser bin area contains mechanical, moving parts. Keep hands and arms clear of this area at all times. If
access to this area is required, power to unit must be disconnected rst.
§ Follett recommends a Follett water lter system be installed in the ice machine inlet water line (standard capacity
#00130229, high capacity #00978957, carbonless high capacity #01050442).
§ Prior to operation, clean the dispenser in accordance with instructions found in this manual.
§ Ice is slippery. Be sure counters and oors around dispenser are clean, dry and free of ice.
§ Do not block right side air intake or top air exhaust.
Specications
air exhaust
16.00
"
(40.7 cm)
4.00
"
(10.2 cm)
3/8
" FPT
water inlet
3/4
" MPT drain
23.5
"
(59.7 cm)
18.00
"
(45.8 cm)
32.00
"
(82.6 cm)
air
intake
Front View Side View Rear View
22.625
"
(57.5 cm)
power cord (NEMA 5-15)
Electrical
§ 115 V, 60 Hz, 1 phase, 11.0A
§ Connect to a 15A dedicated circuit.
Ambient
Air temp* 100 F/38 C Max. 50 F/10 C Min. Best performance below 80 F (27 C)
Water temp
90 F/32 C Max. 45 F/4 C Min. Best performance below 70 F (21 C)
Water pressure (psi/bar) 70/5 Max. 10/0.7 Min.
* Ambient air temperature is measured at the air-cooled condenser coil inlet.
Ambient water temperature is measured in the ice machine reservoir.
Plumbing
12CI425A 12HI425A
Dispenser drain 3/4" MPT 3/4" MPT
Water inlet 3/8" FNPT 3/8" FNPT
Note: Water shut-off recommended within 10 ft. (3 m) of dispenser. Drain to be hard-piped and insulated. Maintain at
least 1/4" per foot (20 mm per 1 m) run of slope.