Spec Sheet

assaabloyesh.com | 800.626.7590
10027 S. 51
st
Street, Ste. 102 Phoenix, AZ 85044 USA
Copyright © 2018, Hanchett Entry Systems, Inc., an ASSA ABLOY Group company.
All rights reserved. Reproduction in whole or in part without the express written
permission of Hanchett Entry Systems, Inc. is prohibited.
Patent pending and/or patent
www.assaabloydss.com/patents
assaabloyesh.com | 800.626.7590
10027 S. 51
st
Street, Ste. 102 Phoenix, AZ 85044 USA
Copyright © 2018, Hanchett Entry Systems, Inc., an ASSA ABLOY Group company.
All rights reserved. Reproduction in whole or in part without the express written
permission of Hanchett Entry Systems, Inc. is prohibited.
Patent pending and/or patent
www.assaabloydss.com/patents
60
Electric Strikes
60
Electric Strikes
Specifications
Certifications
UL 1034, burglary-resistant listed
UL 294 (6th Edition) listed
ANSI/BHMA A156.31, Grade 1
RoHS compliant
Electrical (Continuous Duty)
510 mA at 12 VDC/250 mA at 24 VDC
310-4-1
For both leaves of a pair of doors when spacing of the
vertical rod is between 4" [101.6mm] and 4-3/4" [120.65mm]
PK keeper standard
310-4-2
For both leaves of a pair of doors when spacing of the vertical
rods is between 4-5/8" [111.125mm] and 5-3/8" [136.5mm]
PK keeper standard
310-4-3
For both leaves of a pair of doors when spacing of the
vertical rods is between 5-1/4" [133.35mm] and 6" [152.4mm]
PK keeper standard
310-4-30
For both leaves of a pair of doors when spacing of the vertical
rods is between 2-5/8" [66.675mm] and 3-3/8" [85.725mm]
PK keeper standard
How to Order
Series Keeper Style Fail Secure / Safe Voltage Finish Option (s)
310-4-X F 24D 612 LCBMA
Complete Pacs
(PK) For use
with 3/4"
Pullman style
latchbolts
(blank) Fail Secure
(standard)
12D 12 Volt
605 Bright Brass
LCBMA Latchbolt &
locking cam monitor
with auxiliary switch
606 Satin Brass
1 For use with vertical
rod spacing between
4" and 4-3/4"
F Fail Safe 24D 24 Volt
612 Satin Bronze
613 Bronze Toned
629 Bright Stainless Steel
630 Satin Stainless Steel
2 For use with vertical
rod spacing between
4-5/8" and 5-3/8"
3 For use with vertical
rod spacing between
5-1/4" and 6"
30 For use with vertical
rod spacing between
2-5/8"and 3-3/8
Dimensions
HES Folger Adam 310-4-X Electric Strike
C
A
C
E
D
B
A B C D E
310-4-1
13-3/8"
[339.7mm]
4-3/8"
[111.125mm]
1-13/16"
[46mm]
1-1/2"
[38.1mm]
3/4"
[19mm]
310-4-2
14"
[355.6mm]
5"
[127mm]
1-13/16"
[46mm]
1-1/2"
[38.1mm]
3/4"
[19mm]
310-4-3
14-5/8"
[371.5mm]
5-5/8"
[142.8mm]
1-13/16"
[46mm]
1-1/2"
[38.1mm]
3/4"
[19mm]
310-4-30
12"
[304.8mm]
3"
[76.2mm]
1-13/16"
[46mm]
1-1/2"
[38.1mm]
3/4"
[19mm]
NOTE: Double-door models are available with four different center-
to-center dimensions between latchbolt keepers. Keepers are wide
enough to compensate for vertical-rod exit bolts which may be as
much as 3/8" (10mm) off center-to-center dimension, either way.
NOTE: When using an electric strike in conjunction with a vertical-rod exit device:
1. The bottom rod of the exit device must be removed or made inoperative.
2. The latchbolt of the exit device must be the Pullman or beveled type.
3. The latchbolt must be free-latching and remain projected while
the door is open. Mechanisms that hold the latchbolt retracted
while the door is open, and automatically release it when the
door is closed, must be removed or made inoperative