Supplementary Document
Table Of Contents
Power generator
FV 11001 TRE
Technical parameters
Frequency
Voltage
Nominal power
Maksimum power
Engine
Model
Displacement
Cooling
Cylinder
Stroke
Oil volume
Starting system
Fuel
Fuel tank
Consumption (load 75%)
Noise Lwa
Weight
Lenght
Width
Hight
50 Hz
230 V
9,5 kW
10,5 kW
Vanguard
3854
3
627 cm
Air
2
4
1,7 L
Manual + Electric
starter
Petrol
45 L
4,9 L / h
97 dB(A)
131 kg
790 mm
580 mm
745 mm
Characteristic
§ Voltage stabilization ± 2 %
§ Low level of THD < 4 %
§ Shortcut staring current 300 %
§ Alternator insulation class H
§ Alternator protection IP 23
§ Full single phase power output socket 63 Amps
§ Autonomy (at 75 % load) 9,2 h
§ Outdoor operation without enclosure -
Noise Lwa 97 dB(A)
§ Frame diameter 38 mm
Optional and service equipment
§ Exhaust hose
§ Transportation set
§ Service kit (air filter, spark plugs, engine oil)
Norms and Directives
§ 2000/14/WE
Noise directive 2005/88/WE
§ 2006/42/WE
Machinery directive
§ 2014/35/WE
Low voltage directive
§ 2014/30/WE
EC directive
Update: april 2019
Standard equipment
§ AVR
§ Socket 230 V 16 A
§ Socket 230 V 63 A
§ Overload protection
§ Oil pressure sensor
§ Silencer with exhaust adapter
§ Battery
§ Hourmeter