User Manual
Table Of Contents

10
RedNet X2P dimensions are illustrated in the diagram above.
RedNet X2P weighs 1.04 kg and is equipped with rubber feet for desktop mounting. The baseplate
includes a female 3/8” BSW thread so the unit can be mounted on a microphone stand.
A Kensington Lock slot is located in the left side panel allowing a user to secure the device.
RedNet X2P generates little significant heat and is cooled by natural convection.
Note. The maximum operating environmental temperature is 45°C / 113°F.
Power Requirements
RedNet X2P can be powered from two separate sources: Power-over-Ethernet (PoE) or DC input via
external mains supply.
Standard PoE requirements are: 37.0–57.0 V @ 1–2 A (approx.) – as supplied by many suitably equipped
switches and external PoE injectors. Note that PoE can only be accepted at Network Port 1 and that
power is not transmitted as an output on Network Port 2.
PoE injectors used should be Gigabit capable.
To use the 12V DC input, connect the external plugtop PSU supplied to an adjacent mains outlet.
Only use the DC PSU supplied with RedNet X2P. Use of other external supplies may affect performance or could
damage the unit.
When both PoE and external DC supplies are connected, PoE becomes the default supply.
The power consumption of the RedNet X2P is: DC supply: 13.32 W, PoE: 11.0 W
Please note that there are no fuses in RedNet X2P, or other user-replaceable components of any
type. Please refer all servicing issues to the Customer Support Team (see “Customer Support and
Unit Servicing” on page 21).
Physical Characteristics
104mm / 4.1”
47.5mm / 1.9”
140mm / 5.5”