Operation Manual

Technical Information
Control 2802 Operating Manual 41
Technical Information
Control 2802 Specications
The following are general performance gures taken with Prism
DScope test equipment:
Frequency Response +/- 0.3dB 20Hz to 20kHz
THD + Noise <0.015% @ 1kHz
Noise Mic EIN (20Hz to 20kHz, 150Ohm
source < -127.5dBu
Bus Noise All inputs routed < -80dBu
Mic CMRR 70dB (min. gain)
Firmware Updates
When updates are released to improve control surface
workow, bug xes and add new features, you will need to
update the console rmware.
To do this please visit www.focusrite.com to obtain the latest
rmware from the Control 2802 webpage. Then follow the
simple instructions provided with the rmware download to
ash the upgrade to the console memory.
If you experience any issues please read the Control 2802
FAQ found online at www.focusrite.com.