Operation Manual

10 | P a g e
FOBO Tire Plus sensor units are designed to be robust and operate reliably
24x7 to provide tire information around the clock. It is designed to be water
proof (IP57) and by our special use of custom engineering plastics, it will be
able to withstand road salts or other common automotive chemicals (petrol,
engine oil, car wash shampoo, etc.).
Our designers have designed the sensors to ensure that there is no air leakage
as it replaces the tire‟s original valve cap. There is no need to screw on the
sensor extremely tight. Apply a reasonable hand twist force to ensure the
sensor is securely installed and should be able to be removed by hand with
ease.
When installing the sensors, please follow the on-screen prompt of the FOBO
Tire App. Do not screw on the tire sensors until instructed by the FOBO Tire
App. After installation, in the event the tire sensors positions are mixed up,
usually after performing a tire rotation maintenance, you can easily re-
position the sensors to their correct position by selecting „Rotate Tires‟ on the
FOBO Tire Plus App and follow the on-screen instructions. This eliminates
the need to remove the tire sensors physically.
A missing or damaged tire sensor can be replaced easily through the FOBO
Tire App. You will need to purchase a replacement sensor which you can do
so online at www.my-fobo.com. To replace the sensor, first select
„Disable/Install Sensor‟ on the FOBO Tire App on your car status settings and
the App will prompt you to tap on the tire position that you want to replace
for 5 seconds. The box will then show “Disabled”. Then, select
„Disable/Install Sensor‟ again and tap on the same box and the App will
prompt you to install the replacement sensor. Follow the on-screen instruction
and the replacement sensor will be paired and be ready to use.
NOTE: Battery life span up to Two years is an estimate based on normal
use at 23 °C. Battery life may vary according to usage and climatic
temperature.
Battery life span will change due to the following reasons:
1) Frequent change of pressure threshold setting in the App.
2) Disabling & enabling of sensors.
3) Release & pairing.
4) Removal & screw-on of sensors.
5) Operating under extreme cold/hot temperature.
6) Testing of product.
7) Rotation (refer section 5.4 of this user manual)