User Manual

8223A-SR
FN-LINK
TECHNOLOGY LIMITED 6 Proprietary & Confidential Information
-
MCS=3 PER @ -79 dBm
-76
-
MCS=4 PER @ -76 dBm
-73
-
MCS=5 PER @ -71 dBm
-68
-
MCS=6 PER @ -70 dBm
-67
-
MCS=7 PER @ -68 dBm
-65
- MCS=0
PER @ -89 dBm
-83
-
MCS=1 PER @ -87 dBm
-82
-
MCS=2 PER @ -84 dBm
-80
-
MCS=3 PER @ -81 dBm
-75
-
MCS=4 PER @ -77 dBm
-72
-
MCS=5 PER @ -73 dBm
-68
-
MCS=6 PER @ -71 dBm
-67
- MCS=7 PER @ -70 dBm
-62
Receive Sensitivity
(1
1ac,20MHz)
@10% PER
- MCS=8 PER @ -66 dBm
-60
-
MCS=0 PER @ -87 dBm
-80
-
MCS=1 PER @ -83 dBm
-77
-
MCS=2 PER @ -81 dBm
-74
-
MCS=3 PER @ -78 dBm
-70
-
MCS=4 PER @ -75 dBm
-69
- MCS=5 PER @ -70 dBm
-65
-
MCS=6 PER @ -68 dBm
-64
-
MCS=7 PER @ -66 dBm
-59
-
MCS=8 PER @ -64 dBm
-57
Receive Sensitivity
(1
1ac,40MHz)
@10% PER
- MCS=9 PER @ -63 dBm
-55
-
MCS=0 PER @ -83 dBm
-79
-
MCS=1 PER @ -80 dBm
-76
-
MCS=2 PER @ -78 dBm
-74
-
MCS=3 PER @ -74 dBm
-71
-
MCS=4 PER @ -71 dBm
-67
-
MCS=5 PER @ -69 dBm
-63
-
MCS=6 PER @ -65 dBm
-62
-
MCS=7 PER @ -63 dBm
-61
-
MCS=8 PER @ -60 dBm
-56
Receive Sensitivity
(1
1ac,80MHz)
@10% PER
- MCS=9 PER @ -59 dBm
-54