5. FIELDSTRIPPING
5.1. Disassembling the pistol
It is very important to become familiar with the disassembly procedure of the pistol
as disassembly is required during the cleaning and lubrication procedure which
ensures reliable operation of the pistol. Wear eye protection when disassembling and
cleaning to prevent the possibility of springs, spring-tensioned parts, solvent or other
agents from contacting your eyes.
u Completely unload the pistol
as described in Section 4.8.
v Pull the slide fully rearward
and lock it into its rear
position by pressing the
slide stop upward.
w At the left side of the pistol,
rotate the takedown
lever clockwise.
x While holding it in its rear position with one hand, release the
slide by pushing downward on the slide stop.
Slide Stop
Takedown Lever
Slide Stop
Slide
Frame