Fireplace Manufacturers Inc Outdoor Fireplace User Manual
10
Interior Wall Materials:
Wall materials, such as drywall, should be set ush with
theroughfrontfaceoftheVent-Freereplace.Thiswillallow
forplacementofrequirednon-combustiblesurroundmaterialin
suchawaythatthesurroundmaterialcanlayatagainstthe
nishedwallsurfaceandalsoalignwiththeleadingedgeofthe
rebrickinterioroftheVent-Freereplace(seeFigure 15).
Trim Facings:
Parts of the combustible mantle assembly located along
thesidesofthereboxopening,whichprojectmorethanone
andone-halfinches(1-1/2”)fromthefaceofthereplace,shall
bekeptatleasteightinches(8”)fromthereboxopening.
Adjoining Room Walls:
Interior wall surfaces of adjoining room walls must be at a
minimumhorizontalmeasureoftwentyfourinches(24”)away
fromthenishedopeningoftheVent-Freereplace.
D1
W
1-1/2”
8”MIN.NON-COMBUSTIBLEMATERIAL
FRAMING
Figure 14
Model W D1
MM39VF 43” 73-1/2”
MM44VF 48” 77”
MM49VF 53” 80-1/2”
1-1/2”
8”MIN
20”
MIN
8”MIN.NON-COMBUSTIBLEMATERIAL
FRAMING
Figure 15
Air for Combustion and Ventilation
Energyefcienthomesrequirehomestobeairtightbutatthe
same time provide sufcient fresh air to breathe. Fresh air
enters the home through air conditioning duct vents, around
doorsandwindowsbutalsomustprovideenoughfreshairfor
propercombustiononallfuel-burningappliancesinthehome.
Exhaust fans, replaces, clothes dryers, and fuel-burning
appliancesdrawairfromthehousetooperate.Youmustprovide
adequatefreshairfortheseappliances.Thiswillinsureproper
ventingofventedfuel-burningappliances.
Non-combustible
FlexHose
Figure 16
Exterior
Providing Adequate Ventilation
InaccordancewiththeNationalFuelGasCodeNFPA54/ANSI
Z223.1, Section 5.3, Air for Combustion and Ventilation, all
spacesinhomesfallintooneofthethreefollowingventilation
classications:
1.UnusuallyTightConstruction
2.UnconnedSpace
3.ConnedSpace
Thefollowinginformationwillhelpyouclassifyyourspaceand
provideadequateventilation.
Unusually Tight Construction
Theairthatleaksarounddoorsandwindowsmayprovide
enough fresh air for combustion and ventilation. However,
in homes of unusually tight construction, you must provide
additional fresh air.Unusually tightconstruction isdened as
constructionwhere:
a.Wallsandceilingsexposedtotheoutsideatmospherehave
acontinuouswatervaporretarderwitharatingofoneperm*
orlesswithopeningsgasketedorsealedand...
b.Weatherstrippinghasbeenaddedonopenablewindowsand
doorsand...
c. Caulking or sealants are applied to areas such as joints
aroundwindowanddoor frames,between sole platesand
oors, between wall-ceiling joints, between wall panels, at
penetrations for plumbing, electrical, and gas lines, and
otheropenings.
*Apermisaunitofpermeanceorwatervaportransmission,
theUSperm-inchisdenedasthepassageof1grainofvapor
through1squarefootof1inchthickmaterialin1hourundera
pressuredifferenceof1inchofmercury.
Ifyourhomemeetsallthethreecriteriaabove,youmustprovide
additionalfreshair.