User's Manual

Product description
Profiles Con. (DB25)−Cn10
Pin. # Function Type Note
1 Channel 1 TC Pulse
2 Channel 3 TC Pulse
3 Channel 5 TC Pulse
4 Spare TC Pulse
5 Common Gnd //
6 Common Gnd //
7 Traffic alert TC Lavel
8 Common Gnd //
9 Common Gnd //
10 Common Gnd //
11 Channel 5 TS Level
12 Channel 3 TS Level
13 Channel 1 TS Level
14 Channel 2 TC Pulse
15 Channel 4 TC Pulse
16 Channel 6 TC Pulse
17 n.c. // //
18 Common Gnd //
19 Common Gnd //
20 Common Gnd //
21 Common Gnd //
22 Common Gnd //
23 Channel 6 TS Level
24 Channel 4 TS Level
25 Channel 2 TS Level
Interlock Connector − Cn no. 20
Pin. # Function Type Note
1 Common Gnd //
2 Float Intlk 1 // //
3 Float Intlk 2 // //
Ethernet Connect. (EJ45) − Cn no. 8
Pin. # Function Pin Function
1 TD+ 5 TCT
2 TD− 6 RD−
3 RD+ 7 n.c.
4 n.c. 8 RCT
EIA485 (DB9) − Cn no. 21, 7
Pin. # Function Note
1 Tx+ EIA485/422
2 Tx− EIA485/422
3 Rx+ EIA485/422
4 Rx EIA485/422
5 Common Gnd (frame)
6 Common Gnd (frame)
7 Common Gnd (frame)
8 Common Gnd (frame)
9 Common Gnd (frame)
30
4.2 Contnectors pin assignment
4.2.1 EIA485 − Telemetry − Ethernet − Interlock
4.2.2 TC/TS − Profiles
TC/TS Connector (DB25) − Cn no. 9
Pin. # Function Type Note Sym Comment
1 Interlock TC Level
Status command
Active when grounded
2 Tx On TC Pulse
Pulse command
Active when grounded
3 Tx Off TC
Pulse command
Active when grounded
4 Ref. Power DTM Voltage
0...4V
5 Common Gnd // //
Connected to device
frame
6 n.c. // // // //
7 Exc. Enable TC Level
Status command
Active when grounded
8 n.c. // // // //
9 Common Gnd // //
Connected to device
frame
10 I IPA DTM Voltage
0...4V
11 Mains Fault TS Level
Externally powered
Open = active fault
12 Tx On TS Level
Externally powered
Closed = Tx On
13 Warning TS Level
Externally powered
Open = active warning
14 Alarm Reset TC Pulse
Pulse command
Active when grounded
15 Low Power TC Pulse
Pulse command
Active when grounded
16 Rsr Power TC Pulse
Pulse command
Active when grounded
17 Fwd Power DTM Voltage
0...4V
18 Common Gnd // //
Connected to device
frame
19 n.c. // // // //
20 n.c. // // // //
21 Common Gnd // //
Connected to device
frame
22 V IPA DTM Voltage
0...4V
23 Audio Fault TS Level
Externally powered
Grounded = active alarm
24 Fault TS Level
Externally powered
Open = active alarm
25 Remote TS Level
Externally powered
Grounded = active alarm
(O.C.)
(500ms)
Pulse
(500ms)
(O.C.)
(O.C.)
(O.C.)
(O.C.)
(O.C.)