SDS
AA
Classification: "Cylindrical Lithium"
Chemical System:
Lithium/Iron Disulfide (Li/FeS
2
)
Designation: ANSI 15-LF, IEC-FR6
Nominal Voltage: 1.5 Volts
Compatible With:
Storage Temp: -40°C to 60°C (-40°F to 140°F)
Operating Temp: -40°C to 60°C (-40°F to 140°F)*
Typical Weight: 14.5 grams (0.5 oz.)
Typical Volume: 8.0 cubic centimeters (0.49 cubic inch)
Max Discharge: 3.0 Amps Continuous
(single battery only)
5.0 Amps Pulse (2 sec on / 8 sec off)
Max Rev Current: 2 uA
Lithium Content: Less than 1 gram
Typical IR: 60 to 210 milliohms (depending on method)
Shelf Life: 20 years at 21°C
Shipping: Please refer to PSDS Document
Certifications:
ENERGIZER L91
Industry Standard Dimensions
Milliamp-Hours Capacity
Constant Current Discharge to 0.8 Volts
Ultimate Lithium
mm (inches)
Specifications
*All data shown tested at 21°C unless otherwise stated.
This datasheet contains typical information specific to products manufactured at the time of its publication.
©Energizer Holdings, Inc. - Contents herein do not constitute a warranty.
Discharge Profile
Constant Current Discharge
Temperature Effects on Capacity
Constant Current Discharge
Important Notice
PRODUCT DATASHEET
1-800-383-7323 / USA
1-800-383-7323 / CANADA
1-800-383-7323 US/CAN
www.energizer.com
5.50 (0.217)
Maximum
0.10 (0.004)
Typical
14.50 (0.571)
13.50 (0.531)
1.00 (0.039)
Minimum
7.00 (0.276)
Minimum
50.50 (1.988)
49.50 (1.949)
(+)
(-)
0
1000
2000
3000
4000
0 200 400 600 800 1000
Capacity (mAh)
Continuous Discharge Drain (mA)
AA Lithium AA Alkaline
0.8
1.0
1.2
1.4
1.6
1.8
0 1000 2000 3000 4000
Voltage
Capacity (mAh)
1 mA 10 mA 100 mA
0
500
1000
1500
2000
2500
3000
3500
-60 -40 -20 0 20 40 60 80
Capacity (mAh)
Temperature (°C)
25 mA 250 mA 1000 mA
(alkaline shown for comparison)
EA91,
E91,
NH15,
1215
This battery has Underwriters
Laboratories component
recognition (MH29980)
This Battery has Underwriters
Laboratories component Recognition
Certified for intrinsic safety
710024