Data Sheet

Fluke (U.K.) Ltd.
Fluke TiRx Inspector thermal imager for buildings
Detailed specifications
Temperature Temperature measurement range (not
calibrated below -10 °C)
-20 °C to +100 °C (-4 °F to +
212 °F)
Accuracy
± 5 °C or 5 % (whichever is
greater)
Measurement modes
Smooth auto-scaling and
manual scaling
Imaging
performance
Field of view
23° x 17°
S
patial resolution (IFOV)
2.5 mRad
Minimum focus distance
Thermal lens: 15 cm (6 in)
Focus
Manual
Image frequency
9 Hz refresh rate
Detector type
160 X 120 focal plane array, uncooled
microbolometer
Infrared lens type
20 mm F = 0.8 lens
Thermal sensitivity
(NETD)
0.1 °C at 30 °C (100 mK)
Infrared s
pectral band
7.5 μm to 14 μm
Image presentation Palettes
Ironbow, blue-red, high contrast, grey
Level and span
Smooth auto-scaling and manual scaling of level
and span
Minimum span (in manual
mode
)
2.5 °C (4.5 °F)
Minimum span (in auto
mode
)
5 °C (9 °F)
Image and data
storage
Storage medium
SD memory card (2 GB memory card will store at
least 1200 fully radiometric (.is2) IR or 3000 basic
(.bmp) IR images
File formats
Non-radiometric (.bmp) or fully-radiometric (.is2)
No analysis software required for non-radiometric
(.bmp) files
Export file formats
w/SmartView™ software
JPEG, BMP, GIF, PNG, TIFF, WMF, EXIF, and
EMF