6 Fluke Corporation ScopeMeter 190 Series II
General Specifications
190C Series 190 Series II
199C, 196C, 192C, 215C, 225C, 190-204, 190-104
Input voltage ratings
Rated input voltage and max. fl oating voltage CAT II 1000 V, CAT III 600 V CAT III 1000 V, CAT IV 600 V
Maximum voltage between any contact and earth-ground voltage level
Maximum probe voltage CAT II 1000 V, CAT III 600 V CAT III 1000 V, CAT IV 600 V
Maximum voltage between standard 10:1 probe tip and reference lead
Maximum BNC input voltage 300 V CAT IV
Maximum voltage on BNC input directly
Maximum voltage on meter input CAT II 1000 V, CAT III 600 V
Safety designed banana input connectors
Memory save and recall
Memory locations 15 waveform memories plus 2 recording memories
15 waveform memory locations Stores Scope-trace waveform data (2 traces
each) plus screen-copy plus corresponding
setup
Stores Scope-trace waveform data (4 traces
each) plus screen-copy plus corresponding
setup
2 recording memories Each may contain:
a 100 Screen Replay sequence, or
a ScopeRecord Roll-mode recording (2
traces), or
a TrendPlot recording of 2 measurements
Each may contain:
a 100 Screen Replay sequence, or
a ScopeRecord Roll-mode recording (4
traces), or
a TrendPlot recording of 4 measurements
External data storage On PC, using FlukeView™ Software On PC, using FlukeView™ Software, or
Direct storage on external flash memory
drive through USB host port
Screencopies On PC, using FlukeView Software On PC, using FlukeView™ Software, or
Internally (in instrument) which can be
copied on to external flash memory drive as
.BMP-file, through USB host port
Volatility Data is stored in RAM which is maintained by
the instrument’s main battery
Measurement data is initially stored in RAM,
which is maintained by the main battery
with a 30 seconds back-up when battery is
exchanged. When storing data, this is written
in non-volatile flash-ROM.
Real-time clock Provides date and time stamp information for ScopeRecord, for 100 Screen Replay sequences
and for TrendPlot recordings
Case
Design Rugged, shock-proof with integrated protective holster.
Handstrap and hangstrap included as standard.
Drip and dust proof IP 51 according to IEC529
Shock and vibration Shock 30 g, vibration (sinusoidal) 3 g according to MIL-PRF-28800F Class 2
Display size 115.2 mm x 86.4 mm (4.54 in x 3.4 in);
144 mm (5.67 in) diagonal LCD
127 mm x 88 mm (153 mm diagonal) LCD
Resolution 320 x 240 pixels
Contrast and brightness User adjustable, temperature compensated
Brightness 80 cd/m
2
typ. using power adapter 200 cd/m
2
typ. using power adapter,
90 cd/m
2
typ. using battery power
Mechanical data
Size 256 mm x 169 mm x 64 mm
(10.1 in x 6.6 in x 2.5 in)
265 mm x 190 mm x 70 mm
(10.5 in x 7.5 in x 2.8 in)
Weight (incl. battery) 2 kg (4.4 lb) 2.2 kg (4.8 lb)
Power
Line power Mains adapter/battery charger BC190 included, version depending of country
Battery power Rechargeable NiMH BP190 (installed) Rechargeable double capacity Li-ion battery
BP291 (included). Battery swappable through
easily accessible battery door at the rear of
the instrument.
Battery charge indicator Battery status indicator on instrument screen Battery has built-in status indicator for use
with external charger, next to battery status
indicator on instrument screen