Safety Specifications
3
Tactile Barrier
bbs03f.eps
Figure 1. Tactile Barrier
Safety Specifications
Category Rating: CAT III 1000 V and CAT IV 600 V per EN/IEC61010-1, Pollution Degree 2
) : Tested to US and Canadian standards for compliance to UL 61010-1 and CAN/CSA C22.2
No. 61010-2-32
P : EN 61010-2-32, EN61010-1
EMC Specifications
EMC: EN 61326-1, FCC for emission and immunity
Electrical Specifications
Reference Conditions: 23 ± 5 °C, 20 to 75 % RH (73 ± 41 °F, 20 to 75 % RH); conductor centered in jaw
opening; no dc component; no adjacent conductor
Measurement Range: 1 A to 400 A ac rms
Output: 1 mA/A
Accuracy: 2 % + 0.06 A, 45 Hz to 400 Hz
Typical Bandwidth: 5 Hz to 20 kHz
Working Voltage: 1000 V ac rms, in compliance with EN61010
Common Mode Voltage: 1000 V ac rms from earth ground, in compliance with EN61010
Load Impedance: < 10
Maximum Non-destructive Current: 1000 A
Duty Cycle: 1 A to 400 A continuous
Influence of Adjacent Conductor: < 7.5 mA/A
Influence of Conductor Position in Jaw Opening: ± 1.0 % of reading + 0.05 A