Brochure
FoodPro (Fluke FP)
Temperature Range
Accuracy
(Assumes ambient operating
temperature of 23 °C ± 2 °C)
Response Time
Spectral response
Emissivity
Distance to Spot Size/ Optical
Resolution (D:S)
Typical Working Range
(Target Illumination)
Minimum Target Size
Illumination to
IR Channel Offset
Temperature Range
Accuracy
(Assumes ambient
operating temperature of
23 °C ± 2 °C)
Response Time
Probe Dimensions
Sensor Type
Repeatability
Ambient Operating Range
Relative Humidity
Storage Temperature
Weight/Dimensions
(with Battery)
Power
Battery Life (Alkaline)
Target Illumination Light
Display Hold (7 seconds)
LCD Backlit Display
Temperature Display
Max. Temp. Displayed
Timer
Environmental
Calibration Certificate
Standards
Certifications
Warranty
Included Accessories
Options Accessories
FoodPro Plus (Fluke FP PLUS)
Fluke Corporation
PO Box 9090, Everett, WA USA 98206
Fluke Europe B.V.
PO Box 1186, 5602 BD, Eindhoven, The Netherlands
For more information call:
In the U.S.A. (800) 443-5853 or Fax (425) 446-5116
In Europe/M-East/Africa +31 (0)40 2 675 200
or Fax +31 (0)40 2 675 222
In Canada (800) 36-FLUKE or Fax (905) 890-6866
From other countries +1 (425) 446-5500
or Fax +1 (425) 446-5116
www.fl uke.com
Fluke (UK) Ltd.
52 Hurricane Way
Norwich
Norfolk
NR6 6JB
United Kingdom
Tel: (020) 7942 0700
Fax: (020) 7942 0701
E-mail: industrial@uk.fl uke.nl
www.fl uke.co.uk
Specifications
Fluke. Keeping your world
up and running.
Infrared Thermometer
Probe ThermometerOperational
© Copyright 2006, Fluke Corporation.
All rights reserved. Printed in the Netherlands 03/06
Data subject to alteration without notice.
Pub_ID: 11053-eng
-30 °C to 200 °C
Between 0 °C and 65 °C: ± 1 °C
Below 0 °C: ± 1 °C ± 0.1 degree/degree
Above 65 °C: ± 1.5 % of reading
< 500 ms after initial reading
8-14 microns
Pre-set for food service applications
2.5:1 @ 90 % energy, typical
≈25 mm to 250 mm
12 mm Ø
13 mm
—
—
—
—
—
Within the accuracy specifications of the unit
0 °C to 50 °C
90 % (± 5 %) RH non-condensing
@ 30 °C
-20 °C to 60 °C
100 g
150 mm x 30 mm x 50 mm
1 AA Alkaline
10 hours minimum @ 23 °C
High Brightness LED
•
—
4 digits, 0.2 °C resolution
—
—
IP54 sealing
(hand-washable, non-submersible)
—
Conforms to EN 61326-1 Electromagnetic Emissions and
Susceptibility, EN 61010-1 General Safety
CE NSF
2 year limited
Battery, User’s Guide
—
-35 °C to 275 °C
Between 0 °C and 65 °C: ± 1 °C
Below 0 °C: ± 1 °C ± 0.1 degree/degree
Above 65 °C: ± 1.5 % of reading
< 500 ms after initial reading
8-14 microns
Pre-set for food service applications
2.5:1 @ 90 % energy, typical
≈25 mm to 250 mm
12 mm Ø
13 mm
-40 °C to 200 °C
Between -5 °C and 65 °C: ± 0.5 °C
Below -5 °C: ± 1 °C
Above 65 °C: ± 1 % of reading
7-8 seconds (3 time constants)
Diameter: 3.0 mm
Length: 80 mm
Thin-film Platinum, Class A,
Resistance Thermal Device (RTD)
Within the accuracy specifications of the unit
0 °C to 50 °C
90 % (± 5 %) RH non-condensing
@ 30 °C
-20 °C to 60 °C
150 g
165 mm x 32 mm x 50 mm
9 V Alkaline
10 hours minimum @ 23 °C
High Brightness LED
•
•
4 digits, 0.1 °C resolution
•
Integrated countdown timer, adjustable from 10 seconds
to 7 hours, 59 minutes
IP54 sealing
(hand-washable, non-submersible)
Calibration accuracy with NIST and DKD traceability
Conforms to EN 61326-1 Electromagnetic Emissions and
Susceptibility, EN 61010-1 General Safety
CE NSF
2 year limited
Battery, Carrying Pouch, User’s Manual, Quick Start Guide
Replacement Probe (FP PROBE)
ENEN
Other