User Manual
Model 88 V
Users Manual
28
Table 7. Functions and Trigger Levels for Frequency Measurements
Function Range
Approximate
Trigger Level
Typical Application
M
6 V, 60 V,
600 V, 1000 V
± 5 % of scale Most signals.
M
600 mV ± 30 mV High-frequency 5 V logic signals. (The dc-coupling of the N function can
attenuate high-frequency logic signals, reducing their amplitude enough to
interfere with triggering.)
m
N
600 mV 40 mV Refer to the measurement tips given on page 27.
N
6 V 1.7 V 5 V logic signals (TTL).
N
60 V 4.0 V Automotive switching signals.
N
600 V 40 V Refer to the measurement tips given before on page 27.
N
1000 V 100 V
T g G IL
Frequency counter characteristics are not available or specified for these functions.
^
All ranges ± 5 % of scale AC current signals.
AH
600 µA, 6000 µA 30 µA, 300 µA Refer to the measurement tips given before this table.
60 mA, 400 mA 3.0 mA, 30 mA
AH 6 A, 10 A 0.30 A, 3.0 A