Datasheet

Fluke Corporation
P.O. Box 9090
Fluke Europe B.V.
P.O. Box 1186
5602 BD Eindhoven
The Netherlands
For more information call:
In the U.S.A. (800) 443-5853
or Fax (425) 446-5116
In Europe/M-East/Africa +31 (0)40 2 675 200
or Fax +31 (0)40 2 675 222
In Canada (905) 890-7600
or Fax (905) 890-6886
From other countries +1 (425) 446-5500
or Fax +1 (425) 446-5116
Visit us on the world wide web at:
http://www.fluke.com
Fluke (UK) Ltd
Industrial Sales
The Metro Centre
Dwight Road, Watford
WD1 8HG
United Kingdom
Tel. : +44 20 794 20 700
Fax : +44 20 794 20 701
E-mail : Industrial@uk.fluke.nl
Web : www.fluke.co.uk
Visit us on the world wide web at:
http://www.fluke.co.uk
© Copyright 2001 Fluke Corporation.
All rights reserved.
Printed in the Netherlands 04/01.
Data subject to alteration without notice.
Pub_ID: 10438-eng
Rev. 01
Fluke. Keeping your world
up and running.
Specifications
Summary Specifications (18º to 28ºC, one year)
Function Range Resolution Accuracy
Voltage measure 0 to 28 V .001 V ± (.015% Rdg + 2 counts)
mA measure 0 to 24 mA .001 mA .015% Rdg + 2 LSD
mA source
1
0 to 24 mA .001 mA .015% Rdg + 2 LSD
mA simulate
2
0 to 24 mA .001 mA .015% Rdg + 2 LSD
Loop supply 24 V dc n/a = 24 V
Temperature Coefficient, -10 to 18 ºC, 28 to 55 ºC, ± .005% of range per ºC;
1
Max load, 1200 Ohms; 950 Ohms at 20 mA in HART mode
2
Max applied voltage for simulation, 30 V
Operating Modes
Measure current
Measure current/Loop power
Measure voltage
Simulate current; manual adjust; scroll up/down
Simulate current; 25% steps; 0 - 100% steps
Simulate current; Auto ramp (smooth/step)
Source current; manual adjust; scroll up/down
Source current; 25% steps; 0 - 100% steps
Source current; Auto ramp (smooth/step)
General Specifications
Maximum voltage 30 volts
Non-operating temperature -30 to 60 ºC
Operating temperature -10 to 55 ºC
Relative humidity 0 to 90% (0 to 35 ºC); 0 to 70% (35 to 55 ºC)
Operating altitude 3,000 meters max.
Shock and vibration Per MIL-T-28800 for a Class 2 Instrument
Safety CSA C22.2 No. 1010.1: 1992
EMC EN50082-1:1992 and EN55022:1994 Class B
Size/weight 152 mm L X 70 mm W x 41 mm D
(224 g)
Size/weight with C10 Holster 164 mm L x 75 mm W x 47 mm D
(350 g)
Battery One 9 V alkaline
Battery life 18 hours typical, at 12 mA
Warranty Three years
Ordering Information
Fluke-707 Loop Calibrator
Each calibrator includes: TL75 Test Leads and AC70
Alligator Test Clips, C10 Holster, Instruction sheets (English,
French, German, Spanish, Italian, Dutch, Norwegian,
Danish, Swedish, Finnish, Portuguese, Korean, Chinese,
Japanese), CE and CSA markings.
®