Environmental Specifications
Operating temperature ......................... -10 °C to +50 °C
Storage temperature ............................. -40 °C to +60 °C
Operating humidity
(without condensation)......................... Non condensing (<10 °C)
90 % RH (10 °C to 30 °C)
75 % RH (30 °C to 40 °C)
45 % RH (40 °C to 50 °C)
Ingress Protection ................................ IEC 60529: IP30 with jaw closed
Operating Altitude ................................. 2,000 m
Storage Altitude .................................... 12,000 m
Current Sensor Operating Class ......... IEC 61557-13: Class 1, 100 A/m
Electromagnetic Compatibility (EMC)
International .................................. IEC 61326-1: Industrial Electromagnetic Environment
CISPR 11: Group 1, Class B
Group 1: Equipment has intentionally generated and/or uses conductively-coupled radio
frequency energy that is necessary for the internal function of the equipment itself.