User Manual
  True-rms Digital Multimeters 
  Recording Measurement Data   
 53 
•  Recording session duration expiring. 
•  Manually stopping the recording session. 
Setting up a Recording Session 
Before starting a recording session, setup the Meter for the 
measurements to be recorded. If needed, change the event 
threshold value (see the “Setting the Event Threshold Value 
section later in this manual). Press the softkey labeled Save to 
open the save menu. Using the cursor buttons, move the menu 
selector next to the menu item labeled Record and press the 
softkey labeled Record to open the configuration display. 
There are two variables in setting up a recording session: 
Recording session duration, and sample interval duration. Both 
variables affect the recording length and number of intervals 
recorded. These two variables may interact, in that setting one 
variable may adjust the other variable to fit the recording session 
within the available memory. The percentage of memory 
available at the beginning of a recording session is displayed 
below the duration and sample interval settings. Option values 
can be adjusted as follows: 
The sample interval can be set from one second to 99 minutes 
and 59 seconds. Recording session duration can be set from one 
minute to 99 days 23 hours 59 minutes. 
Table 8. Recording Display 
VAC
Start Time: 
Remaining Time: 2 Hrs 26 mins 
Interval Samples: 47  Events:7
Reference: 121.70 VAC 
06/10/07 07:23:55
Stop
Auto Range
500 VAC0
123.45 VAC
100 200 300 400
Recording
1.75
8:10pm
06/13/07
1
2
3
6
5
4
est31.eps
Item Description 
A 
Recording session in progress icon. 
B 
Time and date when recording session started. 
C 
Time remaining until recording session stops. 
D 
Total number of event records recorded so far. 
E 
Reference value for relative measurements. 
F 