User Manual
  Insulation Multimeter 
  Electrical Specifications 
35 
Electrical Specifications 
AC Voltage Measurement 
Accuracy (all 1587 models) 
Range Resolution 
50 Hz to 60 Hz 
±(% of Rdg + Counts) 
60 Hz to 5000 Hz 
±(% of Rdg + Counts) 
600.0 mV  0.1 mV 
±(1 % + 3)  ±(2 % + 3) 
6.000 V  0.001 V 
±(1 % + 3)  ±(2 % + 3) 
60.00 V  0.01 V 
±(1 % + 3)  ±(2 % + 3) 
600.0 V  0.1 V 
±(1 % + 3)  ±(2 % + 3) 
[1]
1000 V  1 V 
±(2 % + 3)  ±(2 % + 3)
[1]
[1]  1 kHz bandwidth. 
Low-Pass Filter Voltage (all 1587 models) 
Range Resolution 
50 Hz to 60 Hz 
±(% of Rdg + Counts) 
60 Hz to 400 Hz 
±(% of Rdg + Counts) 
600.0 mV  0.1 mV 
±(1 % + 3) 
 +(2 % + 3) 
-(6 % - 3) 
6.000 V  0.001 V 
±(1 % + 3) 
+(2 % + 3) 
-(6 % - 3) 
60.00 V  0.01 V 
±(1 % + 3) 
+(2 % + 3) 
-(6 % - 3) 
600.0 V  0.1 V 
±(1 % + 3) 
+(2 % + 3) 
-(6 % - 3) 
1000 V  1 V 
±(2 % + 3) 
+(2 % + 3) 
-(6 % - 3) 