User Manual
123B/124B/125B 
Users Manual 
70 
Max. Input Voltage A and B 
direct, with test leads, or with VP41 Probe ......... 600 Vrms Cat IV, 750 Vrms maximum voltage. 
with BB120 .......................................................... 600 Vrms 
(For detailed specifications, see Safety, Figure 15 and Figure 16.) 
Max. Floating Voltage, from any 
terminal to ground ................................................ 600 Vrms Cat IV, 750 Vrms up to 400 Hz 
Vertical Accuracy .................................................. ±(1 % + 0.05 range/div) 
Max. Vertical Move ................................................ ±5 divisions 
Horizontal 
Scope Modes ......................................................... Normal, Single, Roll 
Ranges 
Normal: 
Equivalent sampling 
125B, 124B ................................................. 10 ns to 500 ns/div 
123B............................................................ 20 ns to 500 ns/div 
Real time sampling ......................................... 1 μs to 5 s/div 
Single (real time) ............................................. 1 μs to 5 s/div 
Roll (real time) ................................................. 1s to 60 s/div 
Sampling Rate (for both channels simultaneously) 
Equivalent sampling (repetitive signals) .............. up to 4 GS/s 
Real time sampling 
1 μs to 60 s/div ................................................ 40 MS/s 
Time Base Accuracy 
Equivalent sampling ............................................ ±(0.4 % + 0.025 time/div) 
Real time sampling ............................................. ±(0.1 % + 0.025 time/div) 
Glitch Detection .................................................... ≥25 ns @ 20 ns to 60 s/div 
Horizontal Move .................................................... 12 divisions, trigger point can be positioned anywhere across the screen 