User Manual
123B/124B/125B 
Users Manual 
36 
To select the power and harmonics mode: 
1. Push  to open the SETTINGS menu. 
2. Use YZ to highlight POWER HARMONICS. 
3. Push  to open the Ampere Probe on B 
SETTINGS menu. 
If the voltage probe on A and current probe on B 
have not been selected before, complete Step 4 to 
Step 10. 
4. Push 3 to select the probe settings. 
hxv26.eps 
5. Use YZ to highlight SELECT… in Probe A group. 
6. Push  to open the Probe A menu. 
7. Use 
YZ to highlight the Probe A type. 
8. Push  to make the change. 
9. Push 3 to select the probe settings. 
10. Use 
YZ to highlight the Probe B (current clamp) 
type. 
11. Push  to make the change. 
Other settings stay the same. 
Volts/Amps/Watt Measurements 
This function simultaneously shows the voltage and 
current signal. Use this function to get a first impression 
of the voltage and current signal before you examine the 
signal in more detail with the other functions. 
To select the type of measurement: 
1.  Push 2 to select the waveform display. 
2. Push 1 to toggle between the Voltage/Current or 
Power readings. 