Datasheet

Caution!
DO NOT use these probes to measure high
voltages on power distribution systems. The
probes provide high accuracy when used
with a multimeter having 10 megohm input
impedance.
42
High voltage
80K-40 High Voltage
Probe
Extends the voltage measuring
capability of an ac/dc multimeter
to 40,000 V peak ac or dc. This
probe is designed for taking
measurements on low-energy
circuits within equipment only,
such as televisions or photo copy
machines.
Voltage range: 1 kV to
40,000kV, dc or peak ac,
28 kV rms ac
Accuracy: 20 kV to 35 kV;
± 1 % at 20 °C to 30 °C
Division ratio: 1000:1
Meets IEC 61010-031 Type B,
40 kV dc or peak ac, 28 kV rms
ac, (voltage derived from
limited energy transformer)
80K-6 High Voltage Probe
Extends the voltage measuring
capability of an ac/dc digital mul-
timeter to 6,000V peak ac or dc.
This probe is designed for taking
measurements on low-energy
circuits within equipment only.
Voltage range: 0 kV to
6kV, dc or peak ac
Accuracy: dc to 500 Hz ± 1 %;
500 Hz to 1 kHz ± 2 %; above
1 kHz output falls, -30 % at
10kHz
Division ratio: 1000:1
Meets IEC 61010-031 Type B,
40 kV dc or peak ac, 28 kV rms
ac, (voltage derived from
limited energy transformer)
80K-15 High Voltage Probe
Extends the voltage measuring
capability of an ac/dc digital
multimeter to 15,000 V peak ac
or dc. This probe is designed for
taking measurements on low-
energy circuits within equipment
only.
Voltage range: 1 kV to 15 kV dc
or peak ac, 10 kV ac rms
Accuracy: dc ± 2 % 60 Hz;
± 5 %
Division ratio: 1000:1
Meets IEC 61010-031 Type B,
40 kV dc or peak ac, 28 kV rms
ac, (voltage derived from
limited energy transformer)
High frequency
85RF High
Frequency Probe
Converts a dc voltmeter with an
input impedance of 10 megohms
into a high frequency (100 kHz
to 500 MHz) RF voltmeter. The
probes dc output is calibrated to
be equivalent to the rms value of
a sine wave input.
Voltage range: 0.25 V to
3 V ac rms
Maximum input: 30 V rms,
200 V dc
AC to dc ratio: 1:1
Ratio accuracy at 25 MHz and
loaded with 10 megohms
–Above 0.5 V: ± 0.5 dB
–Below 0.5 V: ± 1.0 dB
Add ± 0.2 dB in RF fields of
1V/m to 3 V/m
Frequency response relative to
25 MHz:
100 KHz to 100 MHz
± 0.5 dB
100 MHz to 200 MHz
± 2.0 dB
200 MHz to 500 MHz
± 3.0 dB
Specialty probes
80K-40 80K-15
80K-6
80K-15, 85RF
85RF