Datasheet

Current clamps: AC/DC
i30 i30s 80i-110 s i310s i410 i1010
DC range 30 mA to 30 A 30 mA to 30 A 0.1 A to 100 A 0.1 A to 300 A 1 A to 400 A 1 A to 1000 A
AC range 30 mA to 20 A rms 30 mA to 20 A rms 0.1 A to 70 A 0.1 A to 300 A 1 A to 400 A 1 A to 600 A
Accuracy ± 1 % of reading,
± 2 mA
± 1 % of reading,
± 2 mA
0.1 A to 10 A;
dc to 1 kHz:
± 3 % + 50 mA;
up to 100 A
add 15 %;
up to 20 kHz
add 12 %
30 A range:
1 % + 50 mA
300 A range:
1 % + 300 mA
3.5 % + 0.5 A
for dc or ac
(45 Hz to 400 Hz)
2 % + 0.5 A
for dc or ac
(45 Hz to 400 Hz)
Bandwidth (-3 dB) dc to 20 kHz
(-0.5 dB)
dc to 100 kHz
(-0.5 dB)
100 kHZ dc to 20 kHz 3 kHz 10 kHz
Zero error
adjustment
Yes Yes Yes Yes Yes Yes
Maximum
conductor
diameter
19 mm
(0.75 in)
19 mm
(0.75 in)
11.8 m m
(0.46 in)
19 mm
(0.75 in)
30 mm
(1.18 in)
30 mm
(1.18 in)
Maximum
conductor size
250 MCM 250 MCM 1 AWG 250 MCM 750 MCM or
2-500 MCM
750 MCM or
2-500 MCM
Output levels 100 mV/A 100 mV/A 10 mV/A, 100 mV/A 10 mV/A, 1 mV/A 1 mV/A 1 mV/A
Output cable 1.5 meter with
shrouded dual
banana plug
2 meter with BNC
termination
1.6 meter with BNC
termination
2 meters with BNC
termination and a BNC
to safety shrouded
banana adapter
1.2 meter with
shrouded banana
plugs
1.2 meter with
shrouded banana
plugs
Battery life (hours) 30 30 40 30 60 60
Warranty One-year One-year One-year One-year One-year One-year
Safety CAT III 300 V CAT III 300 V CAT II 600 V,
CAT III 300 V
CAT III 300 V CAT III 600 V CAT III 600 V
AC/DC current clamp specifications
24
i1010