Datasheet
Current clamps: AC
i5s i200 i200s i400 i400s i800 i1000s i3000s
AC range 10 mA to 5 A 0.5 A to 240 A 0.5 A to 240 A 1 A to 400 A 0.5 A to 400 A 0.1 A to 800 A 100 mA to 1000 A 1 A to 3000 A
Accuracy 10 mA to 1 A 1%
+ 5 mA
1 A to 5 A 1%,
48 Hz to 65 Hz
< 3 % +0.5 A
48Hz to 65Hz
< 1 % +0.5 A
48 Hz to 65Hz
2 % + 0.06 A
45 Hz to 400Hz
.5 A to 40A,
2 % + .015A,
5 A to 400A,
2 % + .04A,
45 Hz to 400 Hz
± 2 % of rdg.,
50 Hz to 1 kHz
± 3 % of rdg.,
(typical)
30 Hz to 50 Hz
and 1 kHz to 10
kHz
0.2 to 10 A:
3 % + 0.1 A
10 A to 100 A:
2 % + 0.5 A
100 A to 1000A:
1 % + 1 A
48 Hz to 65 Hz
1 A to 30 A:
2 % + 0.1 A
1 A to 300 A:
2 % + 0.5 A
1 A to 3000 A:
2% + 2 A
48 Hz to 65 Hz
Bandwidth (-3 dB) 40 Hz to 5 kHz 10 kHz to 40 kHz 40 Hz to 40 kHz 5 Hz to 20 kHz 5 Hz to 10 kHz 30 Hz to 10 kHz 10 Hz to 100 kHz 10 Hz to 100 kHz
Maximum
conductor dia.
15 mm
(0.59 in)
20 mm
(0.8 in)
20 mm
(0.8 in)
32 mm
(1.25 in)
32 mm
(1.25 in)
54 mm
(2.13 in)
54 mm
(2.13 in)
64 x 100 mm
(2.52 in x 3.94 in)
Maximum
conductor size
2 AWG 300 MCM 300 MCM 750 MCM 750 MCM 2-500 MCM or
1-1000 MCM
2-500 MCM or
1-1000 MCM
64 mm
(2.52 in)
Output levels 400 mV/A 1 mA/A 10 mV/A
100 mV/A
1 mA/A 10 mV/A
1 mV/A
1 mA/A 1 mV/A
10 mV/A
100 mV/A
10 mV/A
1 mV/A
0.1 mV/A
Output cable 2.5 m to BNC
termination
1.5 m shrouded
banana plugs
2 m to BNC
termination
1.5 m shrouded
banana plugs
2.5 m to BNC
termination
1.6 m shrouded
banana plugs
1.6 m to BNC
termination
2.1 m to BNC
termination
Warranty One-year One-year One-year One-year One-year One-year One-year One-year
Safety rating CAT III 600 V CAT III 600 V CAT III 600 V CAT III 1000 V
CAT IV 600 V
CAT III 1000 V
CAT IV 600 V
CAT III 600 V CAT III 600 V CAT III 600 V
i430-flex i2000 flex i3000s flex-24/i3000s flex-36 i6000s flex-24/i6000s flex-36
AC range 30 A to 3000 A 20 A to 2000 A 30 A to 3000 A 60 A to 6000 A
Accuracy ± 1 % of reading at 25 °C, 50 Hz ± 1 % of range 45 Hz to 65 Hz
Ranges: 20 A, 200A, 2000 A
± 1 % of range, 45 Hz to 65 Hz,
Ranges: 30 A, 300A, 3000 A
±1% of range, 45 Hz to 65 Hz,
Ranges: 60 A, 600A, 6000 A
Bandwidth (-3 dB) 10 Hz to 7 kHz 10 Hz to 20 kHz 10 Hz to 50 kHz 10 Hz to 50 kHz
Maximum
conductor dia.
177 mm (7 in) 177 mm (7 in) 177 mm (7 in) or 265 mm (10.4 in) 177 mm (7 in) or 265 mm (10.4 in)
Maximum
conductor size
610 mm (24 in)
circumference
610 mm (24 in)
circumference
610 mm (24 in)
circumference
610 mm (24 in)/915 mm (36 in)
circumference
Output levels 85 mV at 1000 A rms, 50 Hz 100 mV/A, 10 mV/A, 1 mV/A 100 mV/A, 10mV/A, 1 mV/A 50 mV/A, 5 mV/A, 0.5 mV/A
Output cable 2.5 m to BNC termination 2 m with double shrouded
banana plugs
2.1 m to BNC termination 2 m to BNC termination
Battery life No battery 400 hours 400 hours
Warranty One-year One-year One-year One-year
Safety rating CAT III 1000 V,
CAT IV 600 V
CAT III 600 V CAT III 600 V CAT III 600 V
AC current clamp specifications
Fluke current clamps extend the
current ranges of digital multimeters,
power quality analyzers, and oscillo-
scopes and are available for both
ac and ac/dc environments. Most
clamps are made with a soft, non-
slippery overmold handle to prevent
accidental touching of live wires.
20
i400