Summary specifications for TiR and Insight thermal imagers
Feature TiR4-FT TiR4 TiR3-FT TiR3 TiR2-FT TiR2 Insight
XST
Insight
XS
High-resolution, low noise VOx detector for
high-quality images
320 x 240 160 x 120
Temperature range for building diagnostic
applications
-20 °C to +100 °C 0 °C to +100 °C
High thermal sensitivity for viewing even the
smallest temperature differences
0.05 °C 0.07 °C
180° articulating flexible lens to view images in
every situation
Choice of three interchangeable lenses to cover
every application
Large 5 in. high-contrast color LCD for a clear
picture independent of lighting conditions
Fully radiometric for detailed temperature
analysis and tracking
center
point
imager
only
SmartFocus for best image quality and accurate
temperature measurements
Windows CE based menu structure for ease
of use
Personalized instrument set-up for multiple
user profiles
Compact Flash memory cards store more
than 1000 IR images plus fully radiometric
temperature data
300 300
SmartView reporting and analysis software
included
AutoCapture for making intermittent problems
visible
On-board analysis functions
User defined text annotations for simplified
reporting
Built-in visible light (digital) camera
IR-Fusion blending thermal and visible light
images to easily pinpoint suspect components
IR/Visible Alarm function
Laser pointer for easy targeting
Flash and torch light for high quality images in
dark environments
Imaging performance: thermal
Field of view (FOV)* 23° horizontal x 17° vertical
Spatial resolution (IFOV)* 1.30 mrad 2.60 mrad
Minimum focus distance* 0.15 m
Thermal sensitivity (NETD) 0.05 °C at 30 °C 0.07 °C at 30 °C
Detector data acquisition/image frequency 60 Hz 30 Hz
Focus SmartFocus; one finger continuous focus ring focus
IR digital zoom 2x, 4x, 8x 2x
Detector type Vanadium Oxide (VOx) Uncooled Microbolometer
Detector size 320 x 240 Focal Plane Array 160 x 120
Spectral band 8 µm to 14 µm
Digital image enhancement Automatic full-time enhanced
Temperature measurement
Calibrated temperature range -20 °C to 100 °C (-4 °F to 212 °F) 0 °C to 100 °C
Accuracy ± 2 °C or 2 % (whichever is greater)
Measurement modes TiR2/TiR4: Centerpoint, center box (area min/max, average), moveable spots/boxes, user defined
field/text annotations, isotherms, automatic hot and cold point detection, visible color alarm
above and below
TiR3: Centerpoint, center box (area min/max, average)
Emissivity correction 0.1 to 1.0 (0.01 increments)