Brochure
For more product information and detailed specifications, go to www.fluke.com
13
Summary specifications for TiR and Insight thermal imagers
Feature TiR4-FT TiR4 TiR3-FT TiR3 TiR2-FT TiR2 Insight
XST
Insight
XS
High-resolution, low noise VOx detector for
high-quality images
320 x 240 160 x 120
Temperature range for building diagnostic
applications
-20 °C to +100 °C 0 °C to +100 °C
High thermal sensitivity for viewing even the
smallest temperature differences
≤ 0.05 °C ≤ 0.07 °C
180° articulating flexible lens to view images in
every situation
• • • • • •
Choice of three interchangeable lenses to cover
every application
• • • • • •
Large 5 in. high-contrast color LCD for a clear
picture independent of lighting conditions
• • • • • •
Fully radiometric for detailed temperature
analysis and tracking
• • • • • •
center
point
imager
only
SmartFocus for best image quality and accurate
temperature measurements
• • • • • •
Windows CE based menu structure for ease
of use
•
• • • • •
Personalized instrument set-up for multiple
user profiles
• • • • • •
Compact Flash memory cards store more
than 1000 IR images plus fully radiometric
temperature data
• • • • • •
300 300
SmartView reporting and analysis software
included
• • • • • • • •
AutoCapture for making intermittent problems
visible
• • • •
On-board analysis functions
• • • •
User defined text annotations for simplified
reporting
• • • •
Built-in visible light (digital) camera
• • •
IR-Fusion blending thermal and visible light
images to easily pinpoint suspect components
• • •
IR/Visible Alarm function
• • •
Laser pointer for easy targeting
• • •
Flash and torch light for high quality images in
dark environments
• • •
Imaging performance: thermal
Field of view (FOV)* 23° horizontal x 17° vertical
Spatial resolution (IFOV)* 1.30 mrad 2.60 mrad
Minimum focus distance* 0.15 m
Thermal sensitivity (NETD) ≤ 0.05 °C at 30 °C ≤ 0.07 °C at 30 °C
Detector data acquisition/image frequency 60 Hz 30 Hz
Focus SmartFocus; one finger continuous focus ring focus
IR digital zoom 2x, 4x, 8x 2x
Detector type Vanadium Oxide (VOx) Uncooled Microbolometer
Detector size 320 x 240 Focal Plane Array 160 x 120
Spectral band 8 µm to 14 µm
Digital image enhancement Automatic full-time enhanced
Temperature measurement
Calibrated temperature range -20 °C to 100 °C (-4 °F to 212 °F) 0 °C to 100 °C
Accuracy ± 2 °C or 2 % (whichever is greater)
Measurement modes TiR2/TiR4: Centerpoint, center box (area min/max, average), moveable spots/boxes, user defined
field/text annotations, isotherms, automatic hot and cold point detection, visible color alarm
above and below
TiR3: Centerpoint, center box (area min/max, average)
Emissivity correction 0.1 to 1.0 (0.01 increments)