Electromagnetic Immunity
The Fluke 190-104 and Fluke 190-204 test tools, including standard accessories, conform with the EEC directive
2004/108/EC for EMC immunity, as defined by EN-61326-1, with the addition of the following tables.
Trace disturbance with VPS410 voltage probe shorted (Scope Mode, 10 ms/div):
Table 3. (E - 3V/m)
Frequency No Disturbance Disturbance < 10% of full
scale
Disturbance > 10% of full
scale
80 MHz – 450 MHz All other ranges 100 and 200 mV/div 2.5, 10, 20, 50 mV/div
450 MHz – 2.7 GHz All ranges