User's Manual

345 Calibration Manual Supplement
5 8/13
On page 9, replace Electrical Safety and EMC sections, with:
General Specifications
Maximum working voltage in CAT IV areas:
Current measurement: ............................... 600 V ac rms or dc between conductor & ground
Voltage measurement ................................ 600 V ac rms or dc between either input terminal and ground, or 825 V between
energized phase voltages (delta power config.)
Maximum working voltage in CAT III areas .... 825 V ac rms or dc between either input terminal and ground
Safety ............................................................. IEC 61010-1: 600 V CAT IV, Pollution Degree 2
IP Rating ........................................................ IEC 60529: IP40
Electromagnetic Environment ..................... IEC 61326-1: Portable
Electromagnetic Compatibility .................... Applies to use in Korea only. Class A Equipment (Industrial Broadcasting &
Communication Equipment)
[1]
[1] This product meets requirements for industrial (Class A) electromagnetic wave
equipment and the seller or user should take notice of it. This equipment is intended