User's Manual
PQ Log
Users Manual
42
egd015h.bmp
Figure 24. UNIPEDE DISDIP Table
L1, L2, L3
Click this button to view the number of events of the respective phases.
Lx
Click this button to view the events of all the phases.
Note
If there is a power failure on all three phases, three single events for each
phase are recorded. The response time for events is always 10 ms, which
cannot be modified.
There are two extra lines which sum up short and long interruptions
(<3 min,
≥
3 min).
Events - Measurement Value List
Click the List icon to create a detailed list of all events.
Details such as the time, duration, and minimum or maximum voltage during an event are
displayed. If there is no voltage value given in the table, the event is classified as an
interruption (threshold is defined in limit value file example, 1 % or 10 %).
• The buttons L1, L2, and L3 show only the number of events of the respective
phase
• The button Lx shows the events on all phases
• The button E+i shows events and interruptions
• The button E shows only the events
• The buttons i
st
/ i
lt
show only the short (i
st
) or long (i
lt
) interruptions
Table Summary
Displays the values represented in the Graphical Summary analysis in table form.
In this table, the numerical values for all parameters represented in the graphical
summary can be seen (1
st
column). Also displayed are the limit value (3
rd
column), the
maximum value (4
th
column) and the 95 %-value (5
th
column).