Data Sheet
Technical Data
3000A/6000A Flex 4
for 174x and 173x PQ Analyzers
Electrical specifications
Input ranges |
|
L1, L2, L3, N 30/300/3000/6000 A ac
Measuring range 0.8 A to 6000 A ac
Intrinsic error <2 % of |
|
Position influence max. ± 2 % of m.v. for distance conductor to measuring head >30 mm
Stray field influence <± 2 A for |
ext
= 500 A ac and distance to measuring head >200 mm
Temperature coefficient <0.05 % / K
Current transformer ratio : ≤ 999 kA / ≤ |
|
Ratio selection by job programming for 174x series
by setup menu for 1735
Connection 3-phase, 3-phase + N
2-phase L1 and L3 (2W-meter-method)
7 pole connector
These current probe sets have been
designed for applications with Fluke
1735 and Fluke 1740 series products for
accurate non-intrusive measurement of
AC currents. Using latest technologies
(integrated memory for calibration data)
provides current ranges from 0.8 A up
to 6000 A in a frequency range of 40 Hz
to 5 kHz. The flexis are approved for the
required installation category.