Measurement Range Resolution Accuracy ± ([% of reading] + [counts])
DC millivolts
600.0 mV 0.1 mV
0.5 % + 2
DC volts
6.000 V 0.001 V
0.5 % + 2
60.00 V 0.01 V
600.0 V 0.1 V
Auto volts 600.0 V 0.1 V 2.0 % + 3 (dc, 45 Hz to 500 Hz)
4.0 % + 3 (500 Hz to 1 kHz)
AC millivolts
1
true-rms
600.0 mV 0.1 mV
1.0 % + 3 (dc, 45 Hz to 500 Hz)
2.0 % + 3 (500 Hz to 1 kHz)
AC volts
1
true-rms
6.000 V 0.001 V
1.0 % + 3 (45 Hz to 500 Hz)
2.0 % + 3 (500 Hz to 1 kHz)
60.00 V 0.01 V
600.0 V 0.1 V
Continuity 600 Ω 1 Ω Beeper on < 20 Ω off > 250 Ω; detects
opens or shorts of 500 µs or longer.
Ohms
600.0 Ω 0.1Ω
0.9 % + 2
6.000 kΩ 0.001 kΩ
0.9 % + 1
60.00 kΩ 0.01 kΩ
600.0 kΩ 0.1 kΩ
6.000 MΩ 0.001 MΩ
40.00 MΩ 0.01 MΩ
1.5 % + 2
Diode test
2.000 V 0.001 V
0.9 % + 2
Capacitance
1000 nF 1 nF
1.9 % + 2
10.00 µF 0.01 µF
100.0 µF 0.1 µF
9999 µF 1 µF
100 µF to 1000 µF
1.9 % + 2
> 1000 µF
5 % + 20
Lo-Z capacitance
1 nF to 500 µF
10 % + 2 typical
Temperature
2
(Type-K
thermocouple)
-40 °C to 400 °C 0.1 °C
1 % + 10
2
-40 °F to 752 °F 0.2 °F
1 % + 18
2
AC µamps
true-rms
(45 Hz to 500 Hz)
600.0 µA 0.1 µA 1.5 % + 3 (2.5 % + 3 > 500 Hz)
DC µamps
600.0 µA 0.1 µA
1.0 % + 2
Hz (V or A input)
3
99.99 Hz 0.01 Hz
0.1 % + 2
999.9 Hz 0.1 Hz
9.999 kHz 0.001 kHz
50.00 kHz 0.01 kHz
Notes:
1
All ac voltage ranges except Auto-V/LoZ are specified from 1 % to 100 % of range. Auto-V/LoZ is specified from 0.0 V.
Because inputs below 1 % of range are not specified, it is normal for this and other true-rms meters to display non-
zero readings when the test leads are disconnected from a circuit or are shorted together. For volts, crest factor of
≤ 3
at 4000 counts, decreasing linearly to 1.5 at full scale. AC volts is ac-coupled. Auto-V LoZ, and ac mV are dc-coupled.
2
Temperature uncertainty (accuracy) does not include the error of the thermocouple probe.
3
Frequency is ac coupled, 5 Hz to 50 kHz for ac voltage. Frequency is dc coupled, 45 Hz to 5 kHz for ac current.
Ordering Information
Fluke Model Part Number UPC Codes Product including packaging
Fluke-116/322 2823804 0 95969 39974 6 Height Width Depth Weight
30.48 cm
12 in
22.86 cm
9 in
8.57 cm
3.375 in
0.95 kg
2.09 lb
~
Range 0 – 400 V
400 – 600 V
A
Accuracy 1.8 % ± 5 counts
(50 Hz- 60 Hz)
3.0 % ± 5 counts
(60 Hz - 400 Hz)
AC response Averaging
~
Range 0 – 400 V
400 – 600 V
V
Accuracy 1.2 % + 5 counts
(50 Hz - 400 Hz)
AC response Averaging
...
Range 0 – 400 V
400 – 600 V
V
Accuracy 1 % ± 5 counts
Ω Range 0 – 400.0 Ω
Accuracy 1 % ± 5 counts
Continuity
≤ 30 Ω
Display hold Yes
Size Height 7.5”
Width 2.5”
Depth 1.4”
Jaw opening 1” (26 mm)
Max. wire size 500 MCM
Weight 8 oz.