Specifications for the Fluke 116 DMM
•
Built-in thermometer for HVAC applications
•
Microamps to test flame sensors
•
Low input impedance: helps prevent false readings due to ghost voltage
•
Large white LED backlight to work in poorly lit areas
•
Resistance, continuity, frequency and capacitance
•
Min/Max/Average with elapsed time to record signal fluctuations
•
Compact ergonomic design for one-handed operation
•
Compatible with optional magnetic hanger (ToolPak
™
)
•
CAT III 600 V safety rated
Function Range and resolution Best accuracy
Volts ac/dc 600 V 0.5 % + 2
Current ac/dc 10 A 1.0 % +3
Temperature +400 °C 1.0 % + 18
Resistance 50 kHz 0.9 % + 2
Capacitance 1 nF to 9,999 µF 1.9 % +2
Frequency 5 Hz to 50 kHz 0.1 % +2
Diode 2 V 0.9 % +2