Datasheet
Maximum number of
incidents shown
9
Distance accuracy
± (1 m + 0.1% x length) for reflective incidents
1
± (3 m + 0.1% x length) for non-reflective
incidents
2
Testing speed
5 seconds typical testing time
Connector
Removable/cleanable SC adapter, UPC polish
Fiber types tested
9/125 μm singlemode
Detection of
reflective incidents
3
-45 dB default threshold (user-selectable: -24 dB to
-62 dB in 1 dB increments)
Maximum reflectance
measurement
-24 dB
Loss Threshold
Setting
1.5 dB default warning threshold (user-configurable
from 0.5 dB to 6.1 dB in 0.1 dB increments)
Bulkhead quality
If no fiber is attached or if the connector is dirty,
the troubleshooter displays 0 m or 0 ft.
Live fiber detection
Detects optical signals from 1250 nm to 1625 nm
and shows ACTIVE LINE if a signal is there. Looks
for a signal every 3 seconds after the first detec-
tion. +7 dB maximum input power.
Certifications and
compliance
P Conforms to relevant European Union directives
; Conforms to relevant Australian standards
$ Listed by the Canadian Standards Association
CSA C22.2 No. 61010.1.04
Conforms to FCC Rules, Part A, Class A
1. ± user-configurable Index of Refraction (IOR) error ± the incident location error.
2. ± user-configurable Index of Refraction (IOR) error ± the incident location error.
3. Detects the location of an incident that has a reflectance larger than -62 dB. Detects incidents >2 m after the bulkhead connector when the bulkhead
reflectance is <35 dB. Detects incidents >3 m after an incident when the incident reflectance is <35 dB.
Specifications
Dimensions
17.5 cm H, 7.8 cm W, 3.8 cm D, .35 kg weight
including batteries
Operating temperature
with the battery
0ºC to 50ºC
Non-operating
temperature
-20ºC to 60ºC
Operating relative
humidity
(without condensation)
95% (10ºC to 35ºC)
75% (35ºC to 40ºC)
uncontrolled < 10ºC
Vibration
Random, 5 Hz to 500 Hz, MIL-PRF-28800F CLASS 2
Shock
1-meter drop test
Altitude
9,842 feet/3,000 metres
EMC
EN 61326-1:2004
Battery type
2 AA alkaline batteries (no battery charger)
Battery life
More than 1,500 tests (typical)
Laser safety
Class 1 CDRH
Complies to EN 60825-2
LCD type
Backlit black and white (segments)
Index of refraction
range
1.45 to 1.5 (factory default is 1.468)
Auto turnoff
Automatically turns off after 5 minutes if no
keys are pressed. Backlight turns off first.
Factory calibration
interval
None
Output wavelengths
1550 nm ± 20 nm at 25˚C
Laser classification
Class 1 CDRH Complies to EN 60825-2
Maximum distance
75,459 feet or 23,000 metres