Datasheet
Pro 3000 Toner Specifications
User Interface
Slide Switch selects Continuity or Tone Mode
Push button switch selects SOLID, ALT, or OFF
Tone mode LED
Continuity/Polarity LED
Solid Frequency 1000 Hz nominal
Alternating Frequency 1000/1500 Hz nominal
Over Voltage Protection/td> 60 Vdc in Toner/Polarity Mode
Output Power in Tone Mode 8 dbm into 600 ohms
Output Voltage Level in Continuity Mode 8 Vdc with fresh battery
Battery 9V alkaline
Temperature Operating: -20°C to 60°C, Storage: -40° to 70° C
Dimensions 2.7 in. x 2.4 in. x 1.4 in. (6.9 cm x 6.1 cm x 3.6 cm)
Pro3000F Filtered Probe Specifications
User Interface
ON/OFF button (Push 1 second to activate, Press to turn off, Auto-off after 5 minutes)
Filtered/Unfiltered Mode Button with LED (Green = Filtered, Red = Unfiltered)
Volume dial
Replaceable tip
3.5 mm earphone jack
Frequencies filtered
Pro3000F60 Probe: 60 Hz and its harmonic frequencies
Pro3000F50 Probe: 50 Hz and its harmonic frequencies
Battery 9V alkaline
Temperature Operating: -20° C to 60° C, Storage: -40° to 70° C
Dimensions 9.8 in. x 1.6 in. x 1.3 in. (24.9 cm x 4.1 cm x 3.3 cm)
Pro3000 Analog Unfiltered Probe Specifications
User Interface
ON/OFF pushbutton (Hold to activate, release to turn off)
Volume dial
Replaceable tip
3.5 mm earphone jack
Battery 9V alkaline
Temperature Operating: -20° C to 60° C, Storage: -40° to 70° C
Dimensions 9.8 in. x 1.6 in. x 1.3 in. (24.9 cm x 4.1 cm x 3.3 cm)
3 of 4