Datasheet
Fluke Networks operates in more than 50 countries worldwide.
To find your local office contact details, go to www.flukenetworks.com/contact.
© 2018 Fluke Corporation. Rev: 07/24/2018 4:20 pm (Literature Id: 2798526)
Simplifiber Pro Specifications (included in MS2-FTK)
General Specifications:
Temperature range
Operating: -10°C to 50°C
Storage: -20°C to 50°C
Humidity range
95% (10°C to 35°C) non-condensing;
75% (35°C to 40°C) non-condensing;
uncontrolled <10°C
Certifications CE, CSA, N10140, Class 1 laser-safe
Dimensions
Power meter: 6.4 in x 3.2 in x 1.5 in (16.5 cm x 8.0 cm x 3.9 cm)
MM/SM sources: 5.6 in x 3.2 in x 1.6 in (14.2 cm x 8.1 cm x 4.1 cm)
Weight
Power meter: 11.5 oz (325 g)
MM/SM sources: 9.8 oz (278 g)
Optical Sources
Optical output connector Fixed SC
Emitter type
850/1300: LED
1310/1550: FP Laser
FindFiber: Laser
Emitter wavelengths CE, CSA, N10140, Class 1 laser-safe
Power output (minimum)
MM: ≥ -20 dBm
SM: ≥ 8 dBm minimum;
-7 dBm nominal
Power output stability
(8 hours)
MM: +/- 0.1 dB over 8 hours
SM: +/- 0.25 dB over 8 hours
MM battery life
(2 x AA IEC LR6)
40 hours typical
SM battery life
(2 x AA IEC LR6)
30 hours typical
FindFiber battery life
(2 x AA IEC LR6)
80 hours typical
Optical Power Meter
Power measurement accuracy +/-0.25 dB
Optical connector
Removable adapter; SC adapter standard;
Optional adapters include LC, ST
Detector type InGaAs
Calibrated wavelengths 850, 1300, 1310, 1490, 1550, 1625
Power measurement linearity
850 nm: +/- 0.2 dB; +/- 0.2 dB for power from 0 dBm to -45 dBm, +/- 0.25 dB for power < -45 dBm; 1300 nm, 1310 nm, 1490 nm, 1550 nm, 1625
nm: +/- 0.1 dB;
+/- 0.1 dB for power from 0 dBm to -55 dBm, +/- 0.2 dB for power > 0 dBm and <-55 dBm
Resolution 0.01 dB
Battery life >50 hours typical
Memory 1000 loss or power measurements
Serial communication physical interface USB
5 of 5