PRO3000™ Toner and Probe Users Guide
Checking Polarity
To determine the polarity of a wire pair:
1
Put the toner's slide switch in the TONE position.
2
Connect the unit's red lead to one of the wires, and connect the black lead
to the other wire.
•
If the polarity LED is green, the toner's red lead is more negative than its
black lead.
•
If the polarity LED is red, the toner's red lead is more positive than its black
lead.
•
If the polarity LED is off, there is no DC voltage on the line.
If you know which of the two wires of a telephone line is Tip and which is Ring,
you can determine if the 48 V Central Office Battery is connected in its standard
manner by doing the following:
1
Connect the toner's red wire to Ring of the telephone line.
2
Connect the toner's black wire to Tip of the telephone line.
•
If the polarity LED is green, the CO battery is connected normally.
•
If the polarity LED is red, the CO battery is connected reverse from
normal.
Checking Continuity
The PRO3000 toner's continuity function lets you determine if there is DC
continuity between two un-powered wires.
WCaution
Before connecting the toner to unknown wires in
continuity mode, use the polarity mode to verify that the
wires are not powered. Connecting to powered wires in
continuity mode can damage the toner.
To check for DC continuity between two wires, do the following:
1
Connect the PRO3000 toner's red lead to one of the wires and connect its
black lead to the other wire.
2
Put the slide switch in the CONT position. If there is DC continuity between
the two wires, the continuity LED is red. The brighter the LED, the lower the
resistance between the two wires. The toner indicates continuity up to
10 kΩ.
Using the RJ11 Modular Plug
The PRO3000 toner has an RJ11 phone plug, which you can use instead of the
clip leads when the pair of wires you are testing is terminated with an RJ11 jack.
The RJ11 plug is directly connected to the toner's red and black clip leads. The
plug's green wire (pin 4 of the plug) is connected to the black clip lead; the
plug's red wire (pin 3 of the plug) is connected to the red clip lead. You can use
the RJ11 plug in any of the unit's operating modes.
In-House Communications (Talk Battery)
Two PRO3000 toners can power two telephone test sets on a pair of dry wires
(Figure 5). This lets two people communicate on up to 1 mile (1.6 km) or more of
a dry wire pair.
To use the talk battery:
1
Connect the two toners in series by clipping the red lead of one of the
toners to the black lead of the other toner.
2
Connect one of the toner's free leads to one of the wires of the pair you
want to talk over.
3
Connect the other toner's free lead to one of the leads of your test
telephone.
4
Connect the test telephone's free lead to the other wire of the pair you
want to talk over.
5
Put the slide switch on both toners into the CONT position.
6
Have the person at the other end of the wire pair connect his test
telephone to the wire pair.
7
Put both test telephones in talk mode then begin your conversation.
Replacement Parts and Accessories
To order replacement parts or accessories, contact your local Fluke Networks
distributor.
bff05.eps
Figure 5. Talk Battery
Registration
Registering your product with Fluke Networks gives you access to valuable
information on product updates, troubleshooting tips, and other support
services. To register, fill out the online registration form on the Fluke Networks
website at www.flukenetworks.com/registration.
Contacting Fluke Networks
www.flukenetworks.com
support@flukenetworks.com
+1-425-446-4519 or 1-800-283-5853
•
Australia: 61 (2) 8850-3333 or 61 3 9329 0244
•
Beijing: 86 (10) 6512-3435
•
Brazil: 11 3759 7600
•
Canada: 1-800-363-5853
•
Europe: +44-(0)1923-281-300
•
Hong Kong: 852 2721-3228
•
Japan: 03-3434-0510
•
Korea: 82 2 539-6311
•
Singapore: 65 6799-5566
•
Taiwan: (886) 2-227-83199
Visit our website for a complete list of phone numbers.
Specifications
Description Fluke Networks Model Number
Probe tip
26100103
Earphone
26300000
PRO3000 Toner
User Interface
Slide switch selects continuity or tone mode
Button selects continuous, alternating, or off
Tone mode LED
Continuity/polarity LED
Frequency
Continuous: 1000 Hz nominal
Alternating: 1000 Hz/1500 Hz nominal
Output Power in Tone
Mode
8 dbm into 600
Ω
Output Voltage in
Continuity Mode
8 Vdc with fresh battery
Battery 9 V alkaline
Temperature
Operating: -20 °C to +60 °C
Storage: -40 °C to +70 °C
Altitude To 3,000 m (10,000 ft) maximum
Relative Humidity 5 % to 95 % (non-condensing)
Dimensions
2.7 in x 2.4 in x 1.4 in
(6.9 cm x 6.1 cm x 3.6 cm)
-continued-