Data Sheet
MM battery life (2 x AA IEC LR6) 40 hours typical
SM battery life (2 x AA IEC LR6) 30 hours typical
FindFiber battery life (2 x AA IEC LR6) 80 hours typical
Optical Power Meter
Power
measurement
accuracy
+/-0.25 dB
Optical connector Removable adapter; SC adapter standard; Optional adapters include LC, ST
Detector type InGaAs
Calibrated
wavelengths
850, 1300, 1310, 1490, 1550, 1625
Power
measurement
range
850: 10 to -52 dBm 1300, 1310, 1490, 1550, 1625: 10 to -60 dBm
Power
measurement
linearity
850 nm: +/- 0.2 dB; +/- 0.2 dB for power from 0 dBm to -45 dBm, +/- 0.25 dB for power < -45 dBm; 1300 nm, 1310 nm, 1490 nm, 1550
nm, 1625 nm: +/- 0.1 dB; +/- 0.1 dB for power from 0 dBm to -55 dBm, +/- 0.2 dB for power > 0 dBm and < -55 dBm
Resolution 0.01 dB
Battery life >50 hours typical
Memory 1000 loss or power measurements
Serial
communication
physical interface
USB
Microscanner2 Specifications (Included in MS2-FTK kit)
Test Connectors Twisted-pair: UTP, FTP, SSTP 8-pin modular jack accepts RJ45 and RJ11 Coax: F-connector for 75 Ω, 50 Ω, 93 Ω cables
Cable Tests Tests for open circuits, short circuits, cross-wired pairs, wiremap to TIA-568A/B standards, remote ID locators
Length Measurement Length (up to 460 meters or 1,500 feet) using Time Domain Reflectometry (TDR) Technology
Tone Generator IntelliTone digital tone: [500 KHz]; analog tones:[400Hz, 1KHz]
PoE Detection Solicits and detects the presence of 802.3af compatible PoE devices
Ethernet Port Test Advertised speed of 802.3 Ethernet ports (10/100/1000)
SimpliFiber® Pro Page 7 of 11