Data Sheet
1310/1550 Singlemode Source X X X
1490/1625 Singlemode Source X
Visifault VFL X X X
FI-500 FiberInspector Micro X X
Inspection Probe Tips (LC,SC,1.25mm and 2.5mm Universal) X X
Findfiber Remote ID Source X X X(2)
SC Power Meter Adapter X X X X X X X
ST Power Meter Adapter X X X
LC Power Meter Adapter X X X
Magnetic Strap Attachment X(2) X(2) X(3) X(2) X(3) X(4) X(3)
Carrying Case X X X X X X X
NFC-KIT-BOX Fiber Cleaning Kit X
Microscanner 2 X
Specifications
General Specifications
Temperature range Operating: -10 °C to 50 °C Storage: -20 °C to 50 °C
Humidity range 95% (10 °C to 35 °C) non-condensing; 75% (35 °C to 40 °C) non-condensing; uncontrolled <10 °C
Certifications CE, CSA, N10140, Class 1 laser-safe
Dimensions Power meter: 6.4 in x 3.2 in x 1.5 in (16.5 cm x 8.0 cm x 3.9 cm) MM/SM sources: 5.6 in x 3.2 in x 1.6 in (14.2 cm x 8.1 cm x 4.1 cm)
Weight Power meter: 11.5 oz (325 g) MM/SM sources: 9.8 oz (278 g)
Optical Sources
Optical output connector Fixed SC
Emitter type 850/1300: LED 1310/1550: FP Laser FindFiber: Laser
Emitter wavelengths 850, 1300, 1310, 1490, 1550, 1625
Power output (minimum) MM: ≥ -20 dBm; SM: ≥ 8 dBm minimum; -7 dBm nominal
Power output stability (8 hours) MM: +/- 0.1 dB over 8 hours; SM: +/- 0.25 dB over 8 hours
SimpliFiber® Pro Page 6 of 11
DATASHEET