Auto Wavelength Mode
Auto Wavelength Mode
In auto wavelength mode the source’s signal includes an
identifier that tells the meter which wavelength to measure.
You can set the source to one wavelength or to automatically
switch between wavelengths. When the source is automatically
switching, the meter can automatically measure loss or power at
each wavelength in one test. If you save the measurements, the
meter saves all wavelengths measured in one record.
To set the source to auto wavelength mode:
1
If the AUTO LED is not on, press .
2
Press to manually switch wavelengths (one wavelength
LED is on) or to set the meter to automatically switch
between wavelengths (wavelength LEDs blink alternately).
If the meter detects the auto wavelength signal, AUTO
appears on the display, and the meter automatically
measures at the correct wavelength.
Cleaning Connectors and Adapters
Always clean and inspect fiber connectors before making
connections. Use fiber optic solvent and optical-grade wipes or
swabs to clean connectors as described in the Users Manual.
Changing the Connector Adapter
You can change the meter’s connector adapter to connect to SC,
ST, and LC fiber connectors. See the Users Manual for more
information.