Operation Manual
DTX Series CableAnalyzer
Technical Reference Handbook
2-16
Step 4: Configuring the Fiber Test
4-1
Turn the rotary switch to SETUP.
4-2
Use D to highlight Fiber Loss; then press H.
4-3
Use D to highlight Remote End Setup; then press
H.
4-4
Use DA to highlight Smart Remote; then
press
H.
4-5
Use D and H to enter the settings listed below.
Use C to find settings on other tabs.
•
Bi-Directional: No
•
Number of Adapters: Enter the number of
adapters used in the cabling you will test. For
example, if the cabling has one connector at each
end, enter 2.
•
Number of Splices: Enter the number of splices in
the cabling you will test.
•
Connector Type: Select the type of connector used
in the cabling you will test.
•
Test Method: 1 Jumper
Step 5: Setting the Reference
5-1
Clean the connectors on the tester and the two test
reference cords.
5-2
Turn the rotary switch to SPECIAL FUNCTIONS. Press
H to select Set Reference. If both a fiber module and
twisted pair adapter are attached, select Fiber Module
next.
5-3
Connect the tester and smart remote as shown in Figure
2-10; then press P.
WCaution
If you disconnect the test reference cords from the
tester’s or smart remote’s output, you must set
the reference again to ensure valid
measurements.