Operation Manual
DTX Series CableAnalyzer
Technical Reference Handbook
14-14
Summary of Performance Specifications
Note
All specifications for tests on twisted pair cabling
apply to 100
Ω
cable. Contact Fluke Networks for
information on measurement performance for
cable with a different impedance.
For Category 6/Class E test modes or below, the DTX
CableAnalyzer is compliant with Level III requirements of
TIA-568-C.2-1 and IEC 61935-2.
For Class F test modes, the DTX-1800 is compliant with Level
IV requirements as in the draft 2
nd
edition of IEC 61935-2.
Length
Note
Length specifications do not include the
uncertainty of the cable’s NVP value.
Parameter
Twisted Pair Cabling
Without Remote With Remote
Range 800 m (2600 ft) 150 m (490 ft)
Resolution 0.1 m or 1 ft 0.1 m or 1 ft
Accuracy ± (0.3 m + 2 %);
0 m to 150 m
± (0.3 m + 4 %);
150 m to 800 m
± (0.3 m + 2 %)