Operation Manual
DTX Series CableAnalyzer
Technical Reference Handbook
11-8
Figure 11-4. Network Connectivity Results Screen (DHCP example for twisted pair)
amd06.eps
A
Speeds supported by the switch or hub: 10 Mbit, 100 Mbit, 1000 Mbit.
The current speed is green. Arrows show the connection's duplex
configuration:
B
PoE shows if you ran the Network Connectivity w/PoE test and the device
appears to support Power over Ethernet. The tester requests power from
suspected PoE devices. shows if the device did not supply power
during the test.
SFP shows for a fiber link.
C
Crossover indicator (twisted pair only):
•
Green: either the cable is straight-through, or the cable is a crossover
and the hub or switch crossed pairs 12-36 (MDI on the Negotiation
Details screen).
•
Orange: the tester compensated for a crossover cable by crossing pairs
12-36 (MDI-X on the Negotiation Details screen).
4
3
2
8
9
6
1
5
7