6-2
Common Causes of Copper Cabling
Failures
Table 6-1 describes common causes of test failures on
twisted pair and coaxial cabling.
Table 6-1. Diagnosing Twisted Pair Test Failures
Wire Map: open
Wires connected to wrong pins at connector or
punchdown blocks
Faulty connections
Damaged connector
Tip: The wire map test in Single Test mode features a
scanning function that runs the wire map test
continuously. This function is helpful for locating
intermittent wiring faults.
Wire Map: split pair or reversed pair
Wires connected to wrong pins at connector or punchdown block.
Wire Map: crossed wires
Wires connected to wrong pins at connector or punchdown block.
Mix of 568A and 568B wiring standards (12 and 36 crossed).
Crossover cables used where not needed (12 and 36 crossed).