Operation Manual
DTX Series CableAnalyzer
Technical Reference Handbook
5-4
Table 5-1.
Setting Description
Settings for saving tests
Set to the power frequency in
the area where the tester will be used. This setting helps keep
ac noise (50 Hz or 60 Hz) from affecting resistance measurements.
Coaxial Cable Test Settings (cont.)
SETUP > Instrument
Settings > Store Plot
Data
Standard: The tester displays and saves plot data for insertion loss. The tester saves data for the
frequency range required by the selected test limit.
Extended: The tester saves data beyond the frequency range required by the selected test limit.
No: Plot data is not saved, which lets you save more results. Saved results show only worst margins
and worst values for each pair.
SPECIAL FUNCTIONS >
Set Reference
The tester must be referenced to the smart remote the first time the two units are used together.
You should also set the reference every 30 days. See “Setting the Reference” on page 5-1.
Cable ID Source, Current Fol
der, Result Storage Location (DTX-1800, DTX-1200), Operator, Site,
and Company. See “Preparing to Save Tests” in on page 2-1.
SETUP > Instrument
Settings > Power Line
Frequency