Operation Manual

Certifying Coaxial Cabling
31
To set the reference, do the following:
1
Attach coaxial adapters to the main and remote
testers, screw in the F-connector to BNC adapters; then
make the connections shown in Figure
17.
2
Turn the rotary switch to SPECIAL FUNCTIONS.
3
Highlight Set Reference; then press .
4
Press .
X140.EPS
Figure 17. Coaxial Reference Connections
TEST
LOW BATTERY
TONE
TAL K
FAI L
TEST
PASS
TALK
TALK
MONITOR
ENTER
TEST
SAVE
SPECIAL
FUNCTIONS
SETUP
AUTO
TEST
SINGLE
TEST
EXIT
F1 F2 F3
DTX-CHA003
COAX ADAPTER
DTX-CHA003
COAX ADAPTER
DTX-CHA003
COAX ADAPTER