Operation Manual
Certifying Twisted Pair Cabling
27
Autotest Summary Results for Twisted Pair Cabling
Figure 14 describes the Autotest Summary screen.
Figure 14. Autotest Summary for Twisted Pair Cabling
AMD77F.EPS
PASS: All parameters are within limits.
FAIL: One or more parameters exceed the limit.
PASS*/FAIL*: One or more parameters are within the tester’s
accuracy uncertainty range, and the “*” notation is required by
the selected test standard. See “PASS*/FAIL* Results” on page 28.
Press or to scroll the screen.
If the test failed, press for diagnostic information.
Action prompt for the screen. Use to highlight a
parameter; then press .
: The test passed.
: The parameter was measured, but has no PASS/FAIL limit in the
selected test limit.
X: The test failed.
: See “PASS*/FAIL* Results” on page 28.
The worst margin found for the test.