Operation Manual

DTX-1500 CableAnalyzer
Users Manual
22
Table 2. Twisted Pair Test Settings (cont.)
PASS*/FAIL Only: The tester shows HDTDX and HDTDR results only for Autotests with PASS*,
FA
IL*, or FAIL results.
All AUTOTESTs: The tester shows HDTDX and HDTDR for all Autotests.
Select Enable to test cabling through an unpowered mid-span PoE (Power over Ethernet)
device. See the Technical Reference Handbook for details.
Standard: The tester displays and saves plot data for frequency-based tests such as NEXT,
return loss, and attenuation. The tester saves data for the frequency range required by the
selected test limit.
Extended: The tester saves data beyond the frequency range required by
the selected test
limit.
No: Plot data
is not saved, which lets you save more results. Saved results show worst margins
and worst values for each pair.
The tester must be referenced to the smart remote the first time the two units are used
together. You should also set the reference every 30 days. See “Setting the Reference for
Twisted Pair Cabling” on page 18.
Settings for saving
tests
See “Preparing to Save Tests” on page 17.
Setting Description
SETU
P > Twisted Pair >
HDTDX/HDTDR
SETUP > Twisted Pair >
AC Wir
e Map
SETUP > Instrument
Settings > Store Plot
Data
SPECIAL FUNCTIONS >
Set Refer
ence