General Specifications
Speed of Autotest
Full 2-way Autotest of Category 5e or 6/Class D or E: 9 seconds; Full 2-way Autotest of Category 6A/Class E
A
: 10 seconds
Supported test parameters (test standard
determines parameters and frequency range
reported)
Wire Map, Length, Propagation Delay, Delay Skew, DC Loop Resistance, Insertion Loss (Attenuation), Return Loss (RL), Near End Crosstalk
(NEXT), Attenuation-to-Crosstalk Ratio (ACR-N), ACR-F (ELFEXT), Power Sum ACR-F (PS ELFEXT), Power Sum NEXT, Power Sum ACR-N
Maximum Frequency 500 MHz
Test Result Storage 12,000 Cat 6A with plots
Display 5.7 in LCD display with a projected capacitance touchscreen
Dimensions Main Unit and Smart Remote: 2.625 in x 5.25 in x 11.0 in (6.67 cm x 13.33 cm x 27.94 cm)
Weight 3 lbs (1.36 kg)
Battery Lithium ion battery pack, 7.2 V
Battery Life 8 hours, typical
Battery Charge Time 4 hours (below 40° C, with tester off)
Languages supported English, French, German, Italian, Japanese, Portuguese, Spanish, Chinese, Korean, Russian, Trad Chinese, Czech, Polish, Swedish, Hungarian
Calibration Service center calibration period is 1 year
Integrated Wi-Fi Meets IEEE 802.11 a/b/g/n; dual band (2.4 GHz and 5 GHz)
Environmental Specifications
Operating temperature 32° F to 113° F (0° C to 45° C)
Storage temperature -22° F to +140° F (-30° C to +60° C)
Operating relative humidity (% RH without
condensation)
0% to 90%, 32° F to 95° F: (0° C to 35° C)
0% to 70%, 95° F to 113° F: (35° C to 45° C)
Vibration Random, 2 g, 5 Hz -500 Hz
Shock 1 m drop test with and without module and adapter attached
Safety CSA 22.2 No. 61010, IEC 61010-1 3rd Edition
Altitude 13,123 ft (4,000 m) 10,500 ft (3,200 m) with ac adapter
EMC EN 61326-1: Portable