Chapter 2: How to Certify Twisted Pair Cabling
Settings for Twisted Pair Tests
31
GPU89.EPS
Figure 12. Reference Connections for Twisted Pair Cable
Settings for Twisted Pair Tests
Table 2 gives descriptions of the settings for twisted pair tests. To
set up a project, which includes the settings in Table 2, cable IDs,
and operator names, see Chapter 4.
To set up a twisted pair test
1 On the home screen, tap the test setup panel.
2 On the CHANGE TEST screen, select a twisted pair test to
change, then tap EDIT.
Or to set up a new twisted pair test, tap NEW TEST. If no module
is installed, the MODULE screen shows. Tap the correct copper
module.
3 On the TEST SETUP screen, tap the panels to change settings
for the test. See Table 2.
4 On the TEST SETUP screen, tap SAVE when your test setup is
completed.
5 On the CHANGE TEST screen, make sure the button next to
the test is selected, then tap USE SELECTED.