User Manual

Table Of Contents
Qualifying฀Cabling฀with฀the฀Autotest฀฀
19฀
Autotest฀on฀Twisted฀Pair฀Cabling฀
Notes฀
A฀wiremap฀adapter฀or฀remote฀ID฀locator฀must฀be
connected฀to฀the฀end฀of฀the฀cabling฀for฀the฀
wiremap฀to฀be฀completely฀verified.฀฀
The฀Autotest฀does฀not฀support฀use฀of฀multiple฀
remote฀ID฀locators฀(the฀MultiMap฀function).฀
If฀you฀use฀patch฀cords฀at฀the฀near฀or฀far฀end฀
during฀an฀Autotest,฀Fluke฀Networks฀recommends฀
patch฀cords฀at฀least฀2฀m฀long.฀฀
The฀Autotest฀will฀not฀run฀if฀the฀tester฀is฀
connected฀to฀a฀data฀port,฀or฀detects฀voltage฀or฀a฀
short฀on฀the฀cabling.฀
1 Turn฀on฀the฀tester.฀Turn฀the฀rotary฀switch฀to฀
AUTOTEST.฀
2 To฀change฀the฀tests฀to฀run,฀฀
Jor฀H.฀See฀page฀18.
3 Connect฀the฀tester฀and฀wiremap฀adapter฀or฀ID฀locator฀
to฀the฀cabling.฀Figures฀6,฀7,฀and฀8฀show฀typical฀
connections.฀
4 Press฀
P.฀The฀Autotest฀proceeds฀when฀a฀wiremap฀
adapter฀or฀ID฀locator฀is฀detected.฀The฀analog฀toner฀
turns฀on฀if฀neither฀is฀detected.฀
5 To฀save฀the฀test:฀
a. Press฀
KS.฀฀
b. Use฀
AD฀and฀Hto฀select฀the฀Site,฀Location,฀
or฀Outlet฀field฀for฀editing.฀You฀can฀enter฀up฀to฀
17฀characters฀in฀each฀field.฀See฀Figure฀4฀on฀page฀
13฀for฀details฀on฀editing฀text.฀
To฀see฀a฀list฀of฀predefined฀labels฀for฀the฀
highlighted฀field,฀press฀JList.฀Use฀AD,฀
B C,฀or฀SHIFT฀+฀AD฀to฀move฀through฀the฀
list.฀Use฀
H฀orJ฀to฀select฀an฀entry.฀
c. On฀the฀Enter฀ID฀screen,฀press฀
KS฀to฀save฀
the฀results฀with฀the฀Site,฀Location,฀and฀Outlet
entries฀shown.฀
Note฀
The฀last฀character฀of฀the฀Outlet฀string฀increments฀